Diagnostic Value of Ultrasound Elastography Characterization of Solid Breast Lesions
PDF
Cite
Share
Request
Original Investigation
P: 74-81
August 2017

Diagnostic Value of Ultrasound Elastography Characterization of Solid Breast Lesions

J Acad Res Med 2017;7(2):74-81
1. Mersin Üniversitesi Tıp Fakültesi, Radyoloji Anabilim Dalı, Mersin, Türkiye
2. Mersin Üniversitesi Tıp Fakültesi, Genel Cerrahi Anabilim Dalı, Mersin, Türkiye
3. Mersin Üniversitesi Tıp Fakültesi, Patoloji Anabilim Dalı, Mersin, Türkiye
No information available.
No information available
Received Date: 27.06.2016
Accepted Date: 20.11.2016
PDF
Cite
Share
Request

ABSTRACT

Objective:

In this study, the contribution of ultrasound (US) elastography in the characterization of solid breast masses was investigated.

Methods:

Seventy-five patients (1 male and 74 female, aged between 19 and 80 years) were enrolled. A total of 75 solid breast lesions, for which a biopsy was planned, were evaluated using B-mode US and US elastography during the same session. Using B-mode US, the lesions were classified according to the Breast Imaging Reporting and Data System (BI-RADS); Tsukuba elasticity score was determined and strain ratio was calculated for all lesions. Subsequently, a core biopsy of the lesions was performed. BI-RADS results, Tsukuba elasticity scores, and strain ratio were compared with the histopathological results.

Results:

Of 75 lesions, 47 were benign (62.66%) and 28 were malignant (37.33%). According to the Tsukuba scoring method, the mean score of benign and malignant lesions was 2.31 and 3.96, respectively. The mean strain ratio was calculated to be 4.97±2.94 (0.96–13.20) for malignant lesions and 2.27±1.41 (0.5–5.84) for benign lesions. In statistical analysis, the mean strain ratio of the malignant lesions was significantly higher than that of the benign lesions (p<0.05). BI-RADS classification had the highest sensitivity (89.3%), and the Tsukuba scoring method had the highest specificity (93.6%). Elastographic assessment altered the result in 6 of 8 patients (75%) that B-mode US was missed.

Conclusion:

The combination of B-mode US and US elastography can significantly improve the accuracy of diagnosis and characterization of breast lesions, thereby reducing the unnecessary biopsy rate.

Keywords: BI-RADS, elastography, solid breast lesions, ultrasound